2 Hour Fire Wall Concrete Block

Contributions of plaster or gypsum wallboard shall be determined from ibc tables 722 2 1 4 1 and 722 2 1.
2 hour fire wall concrete block. 2 3 governs materials and assemblies used for structural fire resistance and fire rated separation of adjacent spaces. 1 groupfire resistance rating hr a b e h 4 i r 1 r 2 u3a f 1 h 3b h 5 m s 13 h 1 h 24b f 2 s 2 r 3 r 42 a walls shall not be less than 2 hour fire resistance rated where separating buildings of type ii or v construction. 2 hr 2 hr top and bottom of wall joint for concrete over metal deck simplified drawing 2 29 16 2 hr 2 hr top and bottom of wall joint for flat deck simplified drawing 6 7 16 dwg pdf non fire rated smoke partition cp 506 smoke and acoustic sealant comprehensive drawing 8 26 15. Finishes on concrete masonry walls can increase the fire resistance rating.
Westbrook block is a proud producer of underwriters laboratories ul approved fire rated cmu in both light weight and normal weight densities in 2 3 and 4 hour configurations. A basic 6 inch thick floor panel system has a 4 hour fire resistance rating per ul k909. B for group h 1 h 2 or continue reading detailing concrete masonry fire walls. The fire resistance rating of concrete masonry walls depends on the type of aggregate used in the units.
If wall finishes are used see ibc section 722 3 2. Expanded slag or pumice 4 7 4 5 4 4 4 2 4 0 3 8 3 6 3 4 3 2 3 0 2 7 2 5 2 1 1 9 1 5 a fire resistance rating between the hourly fi re resistance rating periods listed may be determined by linear in terpolation based on the equivalent thickness value of the concrete masonry unit. Design loads fire wall must withstand a minimum 5 lb sq ft 24 kg m 2 and additional seismic loads. Linear interpolation from table 721 3 2 of the florida building code for exposed finish block mix 55 limestone 45 siliceous aggregates.
These blocks while allowing for safe means of egress and fire rating should no longer be looked at as just normal grey cmu. A 2 hour rating can be achieved by a wall with an equivalent thickness of as little as 3 1 5 inches when expanded slag or pumice is used or 4 1 2 inches when siliceous gravel is used as the aggregate. 7 substation transformer firewalls are typically free standing modular walls custom designed and engineered to meet application needs. Chapter 7 of the international building code ibc refs.