2 Hr Rated Glass Door

Fire rated glass ceramic used with specific application window sprinklers.
2 hr rated glass door. 100 0 69 12 33 note. Simpson offers thousands of choices for fire rated doors including 20 minute fire rated wood doors and mdf doors with fire ratings up to 90 minute. For up to 90 min. The wall door frame door and hardware must all be fire rated.
And since simpson fire doors have been designed to match other interior doors your fire rated doors will blend seamlessly with all doors in your home. Wire glass 100 square inches is max exposed glass when wire glass is used. Labeled door frame 2. Single glazing single glazing single glazing.
Fire protective glazing contains dangerous smoke and flame by maintaining its integrity during a fire. 45 200 60 101 60 201 90 102 120 104 supply form. Most steel doors outlast their wood counterparts by over 10 years are better insulated vandal resistant and longer lasting than wood doors or fiberglass doors. Leading usa manufacturer of fire rated glass and framing for use in doors walls windows and floors up to 2 hours for over 35 years.
Superlite x 90 fire protective glazing can be used in doors with a max area of 100 sq. 8 15mm 2 hour 3 hour single leaf fire rated glass door feature. The door must be self closing and positive latching push pull plates cannot be used on a fire rated door and ul approved hinges must be used. K c high quality alloy hinge.
2 the bottom rails on our hinged doors are available in standard size to match the rest of the door or can be made deeper with the addition of a rail extender that gives a more traditional appearance. These doors are most commonly used on the exteriors of a commercial building and on fire rated openings as they are inexpensive and can handle ratings up to 3 hours. 857 single up to 3 hour rated ratings are limited by door size and orientation. Listed by ul and intertek warnock hersey.
Maximum glass light size for a 90 minute 1 1 2 hour door depends on the type of glass being installed. Normal glass will break under heat stress during a fire allowing dangerous smoke to travel to surrounding areas. Exposed area shown above. Note many code are outlawing the use of wire glass due to the hazards of injury from glass breakage.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening and curries makes no representations or warranties concerning what such impact may be in any specific situation. Fire rated doors and frames. Hinged doors in aluminum and glass are ideal in any situation from front doors to utility doors.